Draw the box. Count the energy.
Move a boundary from a kettle to a heat exchanger, then isolate the hot stream. The ledger changes when a transfer crosses the line.
Enlarge for bigger labels, then swipe sideways →
The hot stream loses 100 units/s; the cold stream gains 90 and the surroundings receive 10. Total input is 350, total output is 350, and accumulation is zero.
What this model assumes
All rates are invented teaching values, with no material, equipment or plant measurement implied. Accumulation = enthalpy flow in − enthalpy flow out + heat in − heat out + work in − work out. Electrical input to the kettle is work. Kinetic and potential energy changes and chemical reaction effects are omitted. Energy itself is conserved, including when chemistry changes its form. The exchanger has hot enthalpy 300→200 and cold 50→140, plus 10 to surroundings; both stream enthalpies share a consistent reference. The hot-stream boundary counts 90 transferred to the cold side and 10 to the surroundings as heat out. Internal transfer disappears from the whole-exchanger ledger. The plant is a separate steady illustrative balance, not the exchanger enlarged with invented extra measurements. Kettle rates are instantaneous; no temperature/time prediction or boiling is modeled. Loss means energy leaving the useful process, not energy destroyed.
A transfer inside the box stays off its boundary ledger.
For a control volume, energy accumulates when net enthalpy flow, heat and work entering exceed those leaving. Electricity entering the kettle is work; heat leaking through its walls leaves the useful process.
In the steady exchanger example, the hot stream loses 100 units per second. The cold stream gains 90 and the surroundings receive 10. Nothing accumulates inside the full exchanger.
When the boundary encloses only the hot side, all 100 units per second of transferred heat cross it. Ninety enter the cold stream and ten reach the surroundings. For the whole exchanger, the 90 is an internal transfer and is not counted again.
Hide the mechanism names to see the same signed sum. Energy is conserved even when it becomes less useful. These invented rates illustrate accounting, not a plant simulation or an energy-cost estimate.
Ten units per second leave the exchanger through the wall. What happened?
Taking a real process
beyond the lab?
Jon and I are building RARE Labs toward an autonomous pilot plant builder using AI and robotics. Join the waitlist for updates, and tell us what you’re trying to scale.
Go a little deeper.
- MIT OpenCourseWare, Unified EngineeringFirst law for a control volume ↗
Control-volume accounting for heat, work and enthalpy flows. All interactive rates on this page are illustrative.