The same recipe can make a new impurity.

Slow mixing and a concentrated feed zone can change which reaction wins. Explore an invented process, then compare an entered result with dose-dependent Q3A thresholds.

Teaching model
Local reagent feed zone with an illustrative impurity signal and dose-dependent Q3A thresholdsA feed point can have its own chemistry.A + B → P; P + B → S (impurity)B entersMixing / reaction time: 4.0×Toy hot spot: +23°CRed S forms in the feed zone.Schematic chromatogramPeak height scaled to impurity %Report: 0.050%Identify: 0.100%Qualify: 0.150%0.221% · 1.103 mg/dayInvented process output; not a measured result

Enlarge for bigger labels, then swipe sideways →

Impurity0.221 %
Daily impurity intake1.103 mg/day
Identification thresholdExceeded
Qualification thresholdExceeded

This invented process result contains 0.221% impurity: 1.103 mg/day at 0.5 g/day. Reporting (0.050%) is exceeded; identification (0.100%) is exceeded; qualification (0.150%) is exceeded. These are distinct Q3A triggers, not a pass/fail safety verdict.

What this model assumes

The process picture is an invented teaching model of A+B→P followed by P+B→S. Mixing time = 6/intensity seconds (flask) or 60/intensity seconds (plant); reaction time = 5 seconds; Da = mixing/reaction time. Toy hot-spot rise = 35 × mixing time/(mixing time + feed duration). An Arrhenius-type multiplier is exp[2500(1/298−1/(298+rise))]. Impurity (%) = min(0.8, 0.3 × Da/(1+Da)/(1+feed/10) × multiplier) × feed progress. All process numbers and coefficients are invented, with no calibration, material balance or predictive validity. Real kinetics, cooling, feed geometry, solubility, degradation and work-up are omitted. The schematic peak is scaled to concentration; real chromatographic peak height is not itself a mass percentage. Q3A(R2) thresholds apply to covered new chemically synthesized drug substances, not peptides or oligonucleotides. At ≤2 g/day: report >0.05%; identify >min(0.10%, 1 mg/day); qualify >min(0.15%, 1 mg/day). Above 2 g/day: >0.03%, >0.05%, >0.05%. At an exact threshold this calculator says “not exceeded.” Lower thresholds may apply for unusually toxic impurities; results do not establish product safety or release suitability.

A bigger vessel changes local conditions. An impurity threshold asks a different question.

Consider A + B → P, followed by P + B → S. The desired product is P; S is an impurity. If added B encounters product before it disperses into A, the second reaction can compete. A local hot spot can also change relative rates. Mixing time, feed rate and heat removal therefore matter alongside the recipe.

The flask and plant settings deliberately assign different mixing times. They do not claim that every plant mixes poorly, or that slower feeding always improves every chemistry. All process values, rates, temperatures and concentrations here are invented. Use the entered-sample mode to check a concentration independently of that illustration.

ICH Q3A(R2) covers impurities in certain new chemically synthesized drug substances. It excludes peptides and oligonucleotides, among other categories. Reporting, identification and qualification are separate triggers; exceeding a threshold does not by itself define a safe or unsafe batch.

At a maximum daily dose up to 2 g, the reporting threshold is 0.05%. Identification uses the lower of 0.10% and 1.0 mg/day; qualification uses the lower of 0.15% and 1.0 mg/day. Above 2 g/day the respective thresholds are 0.03%, 0.05% and 0.05%. Lower thresholds can be appropriate for unusually toxic impurities.

At 0.5 g/day, 0.12% impurity corresponds to 0.6 mg/day. It exceeds the identification threshold but not the qualification threshold. At 0.16%, intake is 0.8 mg/day and both thresholds are exceeded. Qualification establishes an impurity’s biological safety at a specified level; identification determines its structure.

At 0.5 g/day, a new impurity is 0.12%. What is triggered beyond reporting?

Taking a real process
beyond the lab?

Jon and I are building RARE Labs toward an autonomous pilot plant builder using AI and robotics. Join the waitlist for updates, and tell us what you’re trying to scale.

Join the RARE Labs waitlist ↗

Go a little deeper.