Energy + flow / INTERACTIVE LESSON 15

Why leave wind behind?

Adjust an ideal turbine’s slowdown and compare flow through the rotor with extracted power.

CHANGE A CONDITION. SEE WHAT FOLLOWS.

Teaching model
Actuator-disc wind-energy limitAt induction 0.3333333333333333, disc speed is 6.000000000000001 m/s, far-wake speed is 3.0000000000000004 m/s, and Cp is 0.5925925925925927.Slow the wind, but keep it flowing.Upstream9 m/sAt disc6 m/sFar wake3 m/sPower coefficient CpBetz peak: 16/27 ≈ 59.3%00.600.20.4Axial induction a

Enlarge for bigger labels, then swipe sideways →

Power coefficient, Cp59.26 %
Ideal mechanical power83.13 kW
Wind at the disc6 m/s
Wind in the far wake3 m/s

At a = 0.3333, wind slows from 9 m/s upstream to 6 m/s at the disc and 3 m/s in the far wake. Cp compares the ideal mechanical power with ½ρAU∞³ using the rotor area A. Its maximum is 16/27 at a = 1/3: disc speed is then 2/3 of upstream speed, and far-wake speed is 1/3. The expanding streamtube preserves mass flow. This model gives 83.13 kW before real rotor and drivetrain losses; it is not a turbine output forecast.

What this model assumes

Classical steady, incompressible, one-dimensional actuator-disc model for an isolated, unducted rotor in an unbounded stream; uniform loading, no wake rotation, blade drag, or generator losses. Illustrative constant air density: 1.225 kg/m³. Udisc = U∞(1−a), Uwake = U∞(1−2a), Cp = 4a(1−a)². The slider stops at a = 0.4; the simple momentum model is not extrapolated into the strongly loaded turbulent-wake regime.

THE IDEA TO TAKE WITH YOU

Extracting more energy from each bit of air also changes how much air flows through.

An ideal actuator disc slows the wind while the streamtube expands. Flow continuity remains part of the model.

The classical power coefficient is Cp = 4a(1 − a)². Its peak is 16/27, about 59.3%, at an induction factor of one third.

This is an aerodynamic idealization for a classical open-flow turbine. It is not an electrical-efficiency claim or a universal bound for every device configuration.

QUICK CHECK

At the classical Betz optimum, does the far-wake air stop?

FROM THE VIDEO · CHANGE THE CONDITIONS

More per kilogram. Fewer kilograms.

The two factors behind the Betz peak.

The two factors behind the Betz peak.

Increase the rotor loading. Energy extracted from each kilogram rises, but the mass flowing through the rotor falls. Their product is the power coefficient.

Assumptions and limits

The same isolated open actuator-disc assumptions as the model above. The mass-flow ratio is relative to ρAU∞. Extracted energy per kilogram is relative to ½U∞². Their product is Cp = 4a(1−a)². These two ratios use the same reference quantities; they are not turbine electrical efficiency. The model stops at a = 0.4 and does not model highly loaded turbulent wakes.

Use the source links below for the underlying thermodynamics and transport models.