FLOW & EQUIPMENT · IMPELLER

You have just invented
the centrifugal pump.

Spin a bowl of water and it climbs the wall. Put a lid on the bowl, give the water one way out and curve the paddles, and you have the machine that moves most of the world's liquids. Then find the one thing it cannot do.

Spin the impeller

D = 200 mm · 1,450 rpm · tip speed 15.2 m/seyeOutletcutwaterThe volute widens toward the outlet; the impeller turns clockwise.030609012015018011.8 mideal head, m
TIP SPEED u15.2 m/s
IDEAL SHUT-OFF HEAD11.8 mideal, illustrative: u² / 2g. Real pumps deliver less.
u = πDN / 60π × 0.200 × 1,450 / 60

Rotation on screen is slowed for readability. The casing is drawn fixed while the impeller changes size, as it does when an impeller is trimmed. Arrows show the flow from the eye, outward through the blades and around the widening volute to the outlet.

SPEED AND DIAMETER

Halve the diameter and double the speed. What happens to the tip speed, and to the head?

u = πDN / 60 with D in metres and N in rpm. H = u² / 2g with g = 9.80665 m/s².

At 1,450 rpm a 200 mm impeller has a tip speed of 15.2 m/s, below the 20 to 60 m/s that KSB lists as typical at an impeller outlet. Spun at that rim speed, the free surface in a bowl would stand 11.8 m higher at the rim than at the centre: an ideal, illustrative shut-off head. Double the speed or the diameter and this number quadruples.

Assumptions and limits

Head here is u² / 2g, the rim rise of the paraboloid free surface in a bowl spinning at the same tip speed (UT Austin, rotational hydrostatics). It is ideal and illustrative: it ignores blade angle, slip, leakage, friction and the flow being delivered. A real pump's head is read from its tested curve, and at duty flow it is less than its shut-off head. Rotation on screen grows with rpm but not in proportion. The casing is drawn fixed while the impeller changes size, as when an impeller is trimmed for a lower head.

THE INVENTION CHAIN

Five steps from a bucket to a pump.

Each step keeps the one before it. The pump in the cutaway is a bucket, a valve, a spinning bowl, a casing and a curved blade, in that order.

  1. BucketLift the water in a container. The shadoof, a counterweighted bucket on a pole, is on record from 2000 BC.Egypt, 2000 BC
  2. Piston pump with flap valvesCtesibius builds an air pump with valves at the bottom, the layout every reciprocating pump still uses.Ctesibius, about 200 BC
  3. Spinning paddle in a bowlSpin the water and its surface becomes a paraboloid. The rim stands u² / 2g higher than the centre.Rotational hydrostatics
  4. Enclosed impellerPapin puts straight vanes inside a casing: the first true centrifugal pump, used for local drainage.Denis Papin, 1687
  5. Curved vanesAppold introduces the curved-vane impeller, the backward-curved blades in the cutaway above.John Appold, 1851

THE CATCH: SUCTION

Starve the eye

eyeLiquid: the eye is 7.66 kPa above the vapour pressurekPa025507510010.0 kPa2.339 kPapressure at the eyevapour pressure
VAPOUR PRESSURE AT 20 °C2.339 kPa
MARGIN ABOVE VAPOUR PRESSURE7.66 kPa0.78 m of water above the vapour pressure
STATE AT THE EYELiquid
ATMOSPHERIC SUCTION LIMIT99.0 kPa10.1 m of water at 20 °C, from a 101.325 kPa atmosphere
  • 1.228 kPa10 °C
  • 2.339 kPa20 °C
  • 4.247 kPa30 °C
  • 7.385 kPa40 °C
  • 12.35 kPa50 °C
  • 19.95 kPa60 °C
  • 31.20 kPa70 °C
  • 47.41 kPa80 °C
  • 70.18 kPa90 °C
  • 101.4 kPa100 °C

Saturation pressure of water from the NIST Chemistry WebBook, rounded to four significant figures. At 20 °C it is 2.339 kPa, not 2.3 bar: about 2 percent of an atmosphere. Between rows the slider interpolates ln p linearly in 1/T.

PRESSURE AT THE EYE, TEMPERATURE OF THE LIQUID

Keep the eye at 10 kPa and heat the water. At what temperature does it boil inside the pump?

Margin = eye pressure − vapour pressure; in metres of water, ÷ (998 kg/m³ × 9.80665 m/s²).

At 20 °C the vapour pressure of water is 2.339 kPa. The eye sits at 10.0 kPa, 7.66 kPa above it (0.78 m of water), so the water stays liquid. From a 101.325 kPa atmosphere the eye can fall 99.0 kPa, about 10.1 m of water, before it boils at this temperature. Friction and the pump's own requirement eat into that ceiling.

Assumptions and limits

Cavitating here means the pressure at the eye has fallen to the vapour pressure of the liquid; the page compares the two directly. Real pumps are specified with NPSH, the margin of total suction head above vapour pressure, and the catalogue value NPSH3 marks a 3 percent drop in developed head under test conditions, not the first bubble: KSB lists incipient cavitation, NPSHi, as a separate and rarely tested criterion. Cavitation is vapour from the liquid itself, not entrained air. Air in the suction line is a priming problem, and common centrifugal pumps cannot evacuate it, so they must be primed before they start. Constants: standard atmosphere 101.325 kPa, g = 9.80665 m/s², water density 998 kg/m³ (NIST lists 998.16 kg/m³ at 20 °C). Between the table rows the vapour pressure is interpolated with ln p linear in 1/T.

WHAT THE BOWL KNEW

The bowl was always the pump.
The casing gives the water one way out.

Spin a bowl of water and the surface climbs the wall into a paraboloid; the rim stands u² / 2g above the centre, where u is the rim speed. A centrifugal pump is that bowl with a lid. The impeller spins the water, pressure rises toward the rim, and the volute collects the flow into one widening channel that leaves through one outlet. Curved blades, Appold's step in 1851, turn the water with less loss than straight paddles.

Head scales with tip speed squared, so speed and diameter are the designer's two levers, and KSB lists 20 to 60 m/s as the typical tip speed at an impeller outlet. The head a pump actually delivers is read from its tested curve, and at duty flow it is less than at shut-off.

The catch is on the suction side. The pump does not pull; the pressure at the eye pushes liquid in, and once that pressure falls to the vapour pressure the liquid boils inside the blades. Water at 20 °C boils at 2.339 kPa, not 2.3 bar, so an open tank at sea level can push water about 10.1 m up into a pump at most, before friction and the pump's own requirement are counted. And because a common centrifugal pump cannot evacuate the air from its suction line, it has to be primed: full of liquid before it starts.

FROM THE FLASK TO THE PILOT

Taking a process
beyond the lab?

Jon and I are building RARE Labs toward an autonomous pilot plant builder with AI and robotics. Join the waitlist and tell us what you are trying to scale.

Join the RARE Labs waitlist ↗

FOLLOW THE EVIDENCE

Sources and model limits